Coaxial Cables

RG59 + 2 x 0.75mm2

Coaxial Cables

Construction

Inner conductor1 

Copper covered steel(CCS) 

0.58 mm 

Dielectric 

Low density PE 

Φ3.70 ± 0.10 mm 

Outer conductor(shield) 

Plain copper 

180 x 0.10 mm 

Shield coverage 

94%

Sheath 

PVC 

Φ6.20 ± 0.10 mm 

Inner conductor 2 

Plain copper 

2 x 0.75 mm2 

Insulated cores 2 

PVC 

2 x Φ1.70 ± 0.10 mm 

Overall sheath 

Φ10.30 ± 0.30 mm 

Electrical & Mechanical Characteristics

Impedance 

75±5 Ohm 

Nominal capacitance 

67 pF/m 

Velocity of propagation 

66%

Insulation resistance 

>2000 Mohm.Km 

Inner conductor resistance 

158 Ohm/Km 

Outer conductor resistance 

11 Ohm/Km 

Operating temperature range 

-25°C - +80 °C 

Cores resistance 

26 Ohm/Km 

Test/Operatig Voltage(max) 

2 KV/0.3 KV 

Copper weight 

29.1 Kg/Km 

Cable weight (approx.) 

147.6 Kg/Km 

Screening effectiveness 

>55 dB 

Attenuation

Frequency(MHz)  

Attenuation (dB/100 m)  

Attenuation (dB/100 ft)  

50 7.4 2.26

100

10.7

3.26

200

15.7

4.79

400

22.7

6.92

500

25.7

7.84

600

28.7

8.75

860

34.8

10.61

1000

38

11.59

Return Loss

30-300 MHz 

>31dB

300-600 MHz 

>28dB

600-900 MHz 

>24dB